Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Lab Circulators and Water Baths - Grainger Industrial Supply

Lab Circulators and Water Baths. 10 results found that include 32 products. Lab circulators, water circulators, and water baths are used for heating, incubating, and other applications where the temperature must be controlled. View All . Applied Filters Clear All .

Standard Operating Procedure - Purdue University

Standard Operating Procedure Base Bath Ryan Mulvenna, February 2014 Description of Process The base bath is located in FRNY 2182. This piece of equipment is used for etching monolayers of glass in the cleaning of reaction vessels for repeated use. In case of spill/contact with base bath contents wash site with copious amounts of water using

SOP Waterbath - Download Documents

Dec 14, 2015 · SOP Waterbath There is document - SOP Waterbath available here for reading and downloading. Use the download button below or simple online reader. The file extension - PDF and ranks to the Documents category.

Baths and Circulators from Cole-Parmer

Water baths and circulators are ideal for maintaining a specified temperature over a long period of time. We offer a wide selection of utility baths, immersion circulators, cooling/heating circulating baths, chillers, and recirculators to meet your laboratory applications.

Department Of Oncology

Standard Operating Procedure (SOP) Title: Precautions against Legionella pneumophila in water baths and incubator water pans 1. Introduction: Legionnaire's disease, caused by Legionella pneumophila, can be found in water systems held at temperatures between 25-45°C. Consequently it is important that any laboratory

Water Baths | JULABO

PURA water baths stand for a straightforward and safe working in the laboratory. The high-quality water baths offer a temperature stability of ± 0.15 °C 2). The working temperature range of +18 °C to 99.9 °C 1) allows a wide range of applications, such as routine laboratory work, temperature applications for samples, incubation, material .

IsoLab - Kerogen Extraction

Place the capped bottles into the shaking water bath at 55°C, 150 rpm overnight. At higher speeds, the water bath tends to stop after several minutes for unknown reasons. But this speed works well enough. Make sure the water is filled up to about ½ the height of the bottles. If it is too full, it may spill.

Installation and Operation Manual

3.05 The interior of the bath is constructed of stainless steel and is designed for operation with distilled water or water solutions, such as water ethylene glycol with corrosion inhibitor's added. The body is made from galvanized steel and is painted for added protection. A gable cover is also provided with the bath.

SOP - Centrifuge Safety - Bridges Lab Protocols

This standard operating procedure outlines the use of centrifuges. Review this document and supply the information required in order to make it specific to your laboratory. In accordance with this document, laboratories should use appropriate controls and personal protective equipment when using centrifuges.

Title: Base Bath Page 1 of 4 Base Bath

Base bath in the Beckman lab is located by the sink at the southeast corner (neareast the door) in room 3724 BI. This SOP includes potential hazards of the base bath, proper equipment required, operation procedure and cautions for the use of the base bath. It aims to guiding the lab users to use the base bath

WATER BATH VERIFICATION PROCEDURE #22

WATER BATH VERIFICATION PROCEDURE #22 . December 1, 1996 . Equipment Checked: WATER BATHS (AASHTO T 209 and T 245) (ASTM D 3666) Purpose: This method provides instructions for checking water temperatures in a bath.

Precision Water Baths | Thermo Fisher Scientific - IN

Thermo Scientific Precision water baths are:. Compact—Save valuable bench space with the small footprint of our general purpose baths.; Effortless—Automatically preheat and turn off your bath for efficient work scheduling with new auto-on and auto-off timers. Intuitive—Simplify parameter setting and monitoring with new icon-based controller interface to help ensure safe operation.

Installation and Operation Manual

3.05 The interior of the bath is constructed of stainless steel and is designed for operation with distilled water or water solutions, such as water ethylene glycol with corrosion inhibitor's added. The body is made from galvanized steel and is painted for added protection. A gable cover is also provided with the bath.

Standard Operating Procedure for Base Bath Cleaning .

Standard Operating Procedure for Base Bath Cleaning Solution 1. General . lab coat, safety glasses, and . the affected area must be immediately rinsed with large amounts of water for at least 15 min. In case of contact with the eye, irrigate the eye for at least 30 .

Shaking Water Bath at Thomas Scientific

This compact shaking water bath utilizes the well proven, belt-less motor drive system from our popular Orbi-Shaker™ Series, with the addition of precision temperature control up to 80°C. The seamless, stainless steel chamber has a 12 liter capacity and includes a universal.

STANDARD OPERATING PROCEDURES (Base-Bath Cleaning .

Polymer Reaction Engineering Laboratory Chemical and Biomolecular Engineering University of Maryland, 20742 Sangyool LEE 1 Adv. Dr. Choi. 09/04/2009 STANDARD OPERATING PROCEDURES (Base-Bath Cleaning Solution) Caution: The Chemicals used in this cleaning procedure are hazardous. Always wear goggles, (face shield), Rubber Gloves, Apron etc.

Standard Operating Procedure

Standards Laboratory SOP 005 . First edition . MONITORING AND LABORATORY DIVISION . MARCH 2014 . TABLE OF CONTENTS . . Note: The Humilab's chamber environment sits inside a water bath. It is . Standard Operating Procedure .

Guidance for Preparing Standard Operating Procedures (SOPs)

----- SOP # A-101.2 Revision No. 2 Page 3 of 9 Supersedes A-100 Effective Date: 06/07/07 A. PURPOSE AND APPLICABILITY: The purpose of this document is to establish a uniform process for the preparation and review of Halifax Environmental Laboratory standard operating procedures (SOPs).

How to Clean a Waterbath (When You Can't Avoid it Any .

Apr 20, 2012 · There's something disconcerting about going to incubate a sensitive and irreplaceable sample in a water bath, only to be confronted by the Creature from the Black Lagoon. Unfortunately, water baths are an inviting habitat for all kinds of life, are often shared by many users, and are a perennially unpopular item to clean. To help you overcome your fears of the monsters lurking in the water .

Standard Operating Procedure - Rotary Evaporator

Standard Operating Procedure Rotary Evaporator in the P.O.W.E.R. Laboratory Elliot Sepos, April 2012 Description of Process Some chemical procedures require a quick and effective separation of substances through evaporation. The Rotary Evaporator is .

Standard Operating Procedure for Base Bath Cleaning .

Standard Operating Procedure for Base Bath Cleaning Solution 1. General . lab coat, safety glasses, and . the affected area must be immediately rinsed with large amounts of water for at least 15 min. In case of contact with the eye, irrigate the eye for at least 30 .

STANDARD OPERATING PROCEDURE FOR .

This Standard Operating Protocol (SOP) manual is a guideline intended to assist as a reference material for routine laboratory activities in mycobacteriology lab. This guideline clearly spells out what is expected and required of personnel while handling mycobacteria during their day-to-day activities in the laboratory. SOPs provide a

Keeping a Clean Water Bath | Blog | WaterBaths.net

May 19, 2017 · Before you start cleaning the water bath, unplug it, let the water temperature drop, and empty the bath. Clean the bath with soapy water and a cloth. Avoid the use of chlorine-containing cleaning supplies, such as bleach, and abrasive scrubbers, because they will damage the bath .

Laboratory Safety - SOPs

A standard operating procedure (SOP) is a detailed, written set of procedures that explains how to use and manage hazardous chemicals, processes, and procedures to prevent or minimize health and safety concerns. According to the USF Chemical Hygiene Plan, SOPs must be developed for hazardous .

Wastewater Laboratory Basics - Illinois Water Environment .

What is a SOP? SOP - Standard Operating Procedures An SOP is a written laboratory specific document which details the method of an operation or analysis with procedures thoroughly described. The SOP is the accepted method for performing certain routine and repetitive tasks. For labs doing NPDES compliance testing, SOPs should be

Fact Sheet: Acid and Base Baths for Glassware Cleaning .

Standard lab attire, lab coat, full-length pants or equivalent, and fully enclosed shoes. Chemical-resistant apron may be worn over the lab coat to protect against splashes. Eye & Face Protection. If there is a splash potential, tight-fitting splash goggles are recommended along with a face shield or protection from a hood sash. Hand Protection

SOP for Operating Procedure of Water Bath : Pharmaceutical .

To lay down the procedure for operation of the water bath. 2.0 SCOPE This procedure is applicable to the water bath, installed at Microbiology laboratory in QC. 3.0 RESPONSIBILITY 3.1 Doing: Technical Assistant 3.2 Checking: Executive/ Manager 4.0 ACCOUNTABILITY Head of the Department 5.0 PROCEDURE 5.1 Ensure that the platform is dry.

Operator's Manuals for Water Baths | PolyScience

Product Type. Models. Manuals; General Purpose Water Bath - Digital: WB02, WB05, WB10, WB20, WB28: En General Purpose Water Bath - Digital

General Purpose Water Baths General Purpose Water Baths

PolyScience Water Baths, available in a range of capacities from 2 liters to 28 liters in both economy and digital models, provide the perfect blend of scientific accuracy and utility for day-to-day laboratory tasks. 86-87 Digital 88-89 Economy 90-91 General Purpose Water Bath Accessories General Purpose Water Baths

Standard Operating Procedure

Standards Laboratory SOP 005 . First edition . MONITORING AND LABORATORY DIVISION . MARCH 2014 . TABLE OF CONTENTS . . Note: The Humilab's chamber environment sits inside a water bath. It is . Standard Operating Procedure .