WFE — Vobis, LLC Pilot Evaporators

Vobis manufactures pilot wiped film evaporator systems (also called agitated thin film evaporators) for high viscosity (to hundreds of thousands of cP), heat sensitive, foaming or fouling applications, for which either high heat transfer or high mass transfer coefficients are required for heat sensitive products.

laboratory evaporator - ParteQ

laboratory evaporator Pulsation free total evaporator for the supply of stable and continuous vapor flows The generation of pulsation free vapor flows is a frequently required yet challenging task in laboratory and pilot scale systems, e.g. in reaction engineering or membrane technology.

LABORATORY AND PILOT PLANTS

With pilot wiped film and short path distillation units, proper and reliable tests can be performed with only 30 kg of crude material. Pilot Plants with Wiped Film Evaporators Standard Sizes of VTA Wiped Film Evaporators in pilot scale Type Evaporator surface [m²] Feed rate [kg/h] Required crude amount [kg] VD 83-6 0.06 5.0 - 12.0 30.0

used rotary evaporators, used rotary evaporators Suppliers .

offers 484 used rotary evaporators products. About 8% of these are Evaporator. A wide variety of used rotary evaporators options are available to you, such as key selling points, power source, and applicable industries.

Thin film evaporators, short path evaporators.

Laboratory, pilot trials and contract distillation starting with product quantities from 1 kg to 1,000 tons are offered as a service. In laboratory and pilot plants in the VTA test center, design parameters for components and distillation units are obtained and the process data for the later operation of industrial scale systems are established.

10L Rotary Evaporator R-1010

> Rotary Evaporator > Pilot-scale Rotary Evaporator > 10L Rotary Evaporator R-1010. 10L Rotary Evaporator R-1010 PDF DownloadShare With: Description Speciafication Related Products Inquiry. Description. Applications. Large capacity and large opening of evaporating flask give larger evaporation surface. The evaporating flask keeps rotating when .

Laboratory and Pilot Systems – VTA & Co., KG

Pilot Plants for Wiped Film and Short Path Applications. Main target is to generate scalable data and results during the pilot tests (with small sample quantities) to enable a later scale up to industrial systems. Furthermore these pilot systems can be used for distillation or .

Rotary Film Evaporator - Thin Film Rotary Vacuum .

A rotary film evaporator is basically a device that has extensive employments in a laboratory setting.It is used to get rid of solvents from samples through the process of evaporation rather than distillation. Compared to the other rotary evaporator, this one is pretty efficient and energy-saving.

Used Pilot Plant for sale. GEA equipment & more | Machinio

Plant, Anhydrous Caustic Pilot, 54#/HR Plant, Anhydrous Caustic Pilot, 54#/HR. Blaw Knox anhydrous caustic plant evaporator / drum flaker. Complete system rated at 126 pounds per hour water evaporation, 54 pounds per hour finished caustic flakes. System includes 11.65 sq. ft. Blaw Knox e.

Wiped-Film Evaporator | Molecular Distillation Equipment

Wiped-Film Distillation Equipment Wiped-Film Stills & Evaporators Wiped-Film Short-Path Distillation and Evaporation Process. Pope Scientific designs and fabricates basic to complex systems using the wiped-film short-path distillation process (also called thin-film distillation) for stills, evaporators and hybrid configurations that include fractional columns with wiped-film distillation units .

T.A.S.T.E. Evaporators - Cook Manufacturing Group, Inc.

With capacities from pilot plant scale to units that produce 100,000+ pound per hour of evaporation, Cook Manufacturing can provide for the evaporation needs in your industry. No detail is left to chance in the construction of an evaporator. Each component is .

pilot plant rotary evaporator, pilot plant rotary .

1-50L Mini &Pilot Plant Scale Vacuum Rotary Evaporator with Vacuum Pump at Factory price for Distillation Equipment . US 630.00- 3000 / Unit 1 Unit (Min. Order) 4 YRS . Xingyang Kori Instrument Factory (13) 100.0% " Customer service " (3 .

Evaporation Technology

Evaporator long medium high high by density difference low/medium filled tubes, 2-phases medium low fairly suited vulnerable suited fairly suited Forced Circulation Evaporator long medium . pilot plants allow us to develop custo - mer specific process solutions by applying tailor-made equipment and complete systems. We work world-

D Velpac® Evaporator The R&D

D‐Velpac® Evaporator Your ideal development tool! LCI's D‐Velpac® evaporator system includes a pilot‐ scale thin‐film evaporator with packaged components mounted on a free‐standing support frame. • Sturdy, stainless steel construction • Fixed clearance rotor (wiper blade option available upon request)

Vobis, LLC Pilot Evaporators

Vobis, LLC Pilot Evaporator Systems. Vobis has over 25 years of working experience in the design and manufacture of evaporation and crystallization pilot plant systems (in addition to manufacturing production scale systems).

Thin Film Evaporator for Evaporation System | De Dietrich .

This provides highest evaporation rates means shortest residence time in the evaporator at lowest temperatures permitting the production of high quality temperature sensitive products. The vapors are mostly guided upwards in a counter current manner to a down coming condenser. A typical flow chart of a pilot plant like system can be seen below:

Pilot-scale investigation of effectiveness of evaporation .

information on evaporator performance, i.e., the performance of real evaporators working with real products over real concentration steps. The aim of this study was to compare heat and mass balance using a pilot-scale, single-stage vacuum falling-film evaporator composed of three tubes in series, for the evaporation of skim milk and water.

20L Rotary Evaporator R-1020

> Rotary Evaporator > Pilot-scale Rotary Evaporator > Rotary Evaporator 20L R-1020. Rotary Evaporator 20L R-1020 PDF DownloadShare With: Description Speciafication Related Products Inquiry. Description . Applications. Large capacity and large opening of evaporating flask give larger evaporation surface. The evaporating flask keeps rotating when .

Pilot-scale Rotary Evaporator

> Rotary Evaporator > Pilot-scale Rotary Evaporator. what we do. Rotary Evaporator Glass Reactor Temperature Control Pressure Control Stirrer New Technology Products. Rotary Evaporator 20L R-1020. 10L Rotary Evaporator R-1010. 5L Rotary Evaporator R-1005. 50L Rotary Evaporator R-1050.

LABORATORY AND PILOT PLANTS

With pilot wiped film and short path distillation units, proper and reliable tests can be performed with only 30 kg of crude material. Pilot Plants with Wiped Film Evaporators Standard Sizes of VTA Wiped Film Evaporators in pilot scale Type Evaporator surface [m²] Feed rate [kg/h] Required crude amount [kg] VD 83-6 0.06 5.0 - 12.0 30.0

Thin film evaporators, short path evaporators.

Laboratory, pilot trials and contract distillation starting with product quantities from 1 kg to 1,000 tons are offered as a service. In laboratory and pilot plants in the VTA test center, design parameters for components and distillation units are obtained and the process data for the later operation of industrial scale systems are established.

Short path evaporators from laboratory to production scale

In addition, the cross section area of flow is equal to the evaporator surface, so that there is only a minor pressure drop between evaporator and condenser. The special design of short path evaporators allows operating pressures, also on industrial scale distillation systems, down to 0.001 mbar.

Pilot plant evaporators - Food Engineering

API Heat Transfer pilot plant Schmidt evaporators validate the quality, taste and color of finished product. Evaporation of product can occur under vacuum and low temperatures, or at high pressures with high-pressure steam. An optional hot water loop can be used for heat-sensitive products.

Pilot Plant Evaporators - Cook Manufacturing Group, Inc.

Pilot Plant Test T.A.S.T.E. Evaporator Capability Contact Us for your testing needs. Minimum 2500 gallons/9500 liters of material required for testing. Contact Us Today! Cook Manufacturing Group Pilot Plant Evaporators Cook Manufacturing now has pilot plant evaporators set up at our facility in Frostproof, FL to provide full testing capability for your product, as well as [.]

Pilot Scale Reactors | Pfaudler

Pfaudler glass lined steel pilot scale reactors are ideal for pilot or kilo scale tests of new processes in corrosive media for chemical and pharmaceutical. . Our Wiped Film Evaporator (Short Path Evaporation Technology) is ideal for the distillation of vitamin E tocopherols, sterols, vitamin C, omega 3 fatty acids and other heat sensitive .

T.A.S.T.E. Evaporators - Cook Manufacturing Group, Inc.

With capacities from pilot plant scale to units that produce 100,000+ pound per hour of evaporation, Cook Manufacturing can provide for the evaporation needs in your industry. No detail is left to chance in the construction of an evaporator. Each component is .

Used Pilot Plant for sale. GEA equipment & more | Machinio

Plant, Anhydrous Caustic Pilot, 54#/HR Plant, Anhydrous Caustic Pilot, 54#/HR. Blaw Knox anhydrous caustic plant evaporator / drum flaker. Complete system rated at 126 pounds per hour water evaporation, 54 pounds per hour finished caustic flakes. System includes 11.65 sq. ft. Blaw Knox e.

RE Series 10L 20L 30L 50L Manual Lifting Rotary Evaporator .

Jul 07, 2020 · The video shows how to install pilot scale 10L 20L 30L 50L manual lifting rotary evaporator RE Series. More info, please feel free to contact me. Audrey Cheng Email: [email protected] .

Thin Film & Short Path Evaporators Process Development

The scale of equipment in the VTA Development Center includes: Laboratory Scale (glass) equipment. Stainless Steel "Mini-Plant" to process 5 kg/hr. Pilot Scale for a fully scalable trial and process guarantees; The equipment available includes: Wiped Film Evaporator; Thin Film Evaporator; Short Path Evaporator; Fractional Distillation Column

Processing Equipment | CDR

Single Effect Batch Evaporator with wide gap plate heat exchanger and large vacuum pump to facilitate processing a wide range of products including heat sensitive proteins. It has a design specification to evaporate 250 pounds of water per hour (given an effect boiling temperature of 130º F). APV PILOT SCALE ONE STAGE SPRAY DRYER