solution was concentrated under reduced pressure/rotovap and run through a silica gel plug using hexane as eluent. After removing the hexane under reduced pressure/rotovap, the resulting oil was purified via vacuum distillation and yielded (3) (3.06 g, 41%) as a colorless oil. 19F (376 MHz, CDCl 3): δ -130.5 (s, 2F). 1H (400 MHz, CDCl

Solvent Recycling and Azeotropes

The most common example is the azeotrope between water and ethanol (grain alcohol). Water boils at 100 ºC and ethanol boils at 78.3 ºC. The mixture will boil at 78.2 ºC and have a composition of 95% ethanol and 5% water by volume.

Increase your distillation efficiency

Tetrahydrofurane (THF) C 4 H 8 O 249 Toluene C 7 H 8 48 Trichloroethylene C 2 HCl 3 119 Water H 2 O 42 Xylene C 8 H 10 15 *Pressure in mbar for boiling point at 30 °C (heating bath 50 °C) List of Solvents Evaporation 094141 en 1508/Technical Data subject to alterations/Quality System ISO 9001 Quality in your hands

Be wary of THF, an explosion just occured in the lab were .

My undergrad lab had a plexiglass enclosure around the THF still, with a little door that you opened to get the solvent. It would not have contained a fire for long, but it would presumably have caused the fire to go upwards rather than outwards.

How To - University of Rochester

©2020 Alison Frontier, University of Rochester. Supported by a grant from the National Science Foundation. NSF Funding {+} This material is based upon work supported by the National Science Foundation under Grant Number CHE-1565813. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect .

Preparation of optically active hydrazines and amines - E .

Oct 05, 1993 · A process for the asymmetric hydrogenation of N-acylhydrazones to optically active N-acylhydrazines in the presence of a chiral phospholane catalyst complex, a process for the reductive N- .

SLC46A3 Is Required to Transport Catabolites of .

rotovap to yield a solid residue. The residue was purified by preparative HPLC (Luna Silica, 21.2 150 mm, 5 mm column; 20 mL/minute isocratic elution; 20% acetonitrile/MTBE) to yield 994 mg of DM1-SMCC (8) as a white solid (73% yield, potency adjusted). Generation of ADC Anti-EGFRvIII Ab-MCC-DM1 was conjugated as previously described (16).

Lesson Learned - Peroxide Explosion Injures Campus Researcher

The evaporation in the rotovap concentrated the peroxides in the bottom of the glass reaction vessel and any movement of the vessel could cause the now dry and shock sensitive peroxides crystals to explode. Below is a photo of what remained after the explosion. Note that the lower round-bottomed flask from the rotovap exploded

Erowid Chemistry Vaults : Organic Solvents Table of Properties

Notes: "M" in the water solubility column means completely Miscible in water. The values in the table below except for relative polarities have been extracted from MSDS compilations (see section II-B-4 of the Chemistry Webercises Directory) or the ChemFinder Web Server.Values for relative polarity have been extracted from: Christian Reichardt, Solvents and Solvent Effects in Organic Chemistry .

Reflux - Wikipedia

Reflux in industrial distillation. The term reflux is very widely used in industries that utilize large-scale distillation columns and fractionators such as petroleum refineries, petrochemical and chemical plants, and natural gas processing plants.. In that context, reflux refers to the portion of the overhead liquid product from a distillation column or fractionator that is returned to the .

Solved: 1. Draw The Two Structures For The Markovnikov And .

Let it sit for 10 or 15 minutes to dry. 8. Decant your dried organic mixture into a WEIGHED rotovapor round bottom flask. Distill off the organic solvent in the Rotovap (your TA will help you keep the warming vat COOL) 87 Page 9 Rotovap your round bottom flask until the amount of liquid in your flask no lon reduces in volume. 10.

VX-445, Elexacaftor, エレクサカフトル – Drug Approvals .

Jun 18, 2019 · [00258] Tetrahydrofuran (THF, . The mixture was slurried at 45 °C for 30 mins, and then distilled off 1-2 volumes of solvent. The slurry in the rotovap flask was filtered and the solids washed with heptane (3.575 L) and pulled dry. The solid was further dried in vacuo (50 °C, 15 mbar) to give tert-butyl 5-oxo-1H-pyrazole-2-carboxylate .

A nanobuffer reporter library for fine-scale imaging and .

After 8 h polymerization at 40 °C, the reaction mixture was diluted in 10 ml tetrahydrofuran (THF), and the mixture was passed through a neutral Al 2 O 3 column to remove the catalyst. The organic solvent was removed by rotovap. The residue was dialysed in distilled water and lyophilized to .

Hydrodecarboxylation of Carboxylic and Malonic Acid via .

S6! 1-((benzyloxy)carbonyl)piperidine-4-carboxylic acid: Prepared according to previously published literature procedure. Analytical data were in agreement with literature values7. 2-benzyl-2-methylmalonic acid: To a 250 mL round bottom flask was added 1.2 g (2.0 equivalents) of sodium hydride and 160 mg of potassium tertbutoxide (0.1 equivalents), followed by 75 mL of dry DMF.

How to get the product (which is a biosurfactant) out of .

Take a good look at the solid left in the rotovap flask, and check with tetrahydrofuran to see if there is another bio-surfactant left. I wouldn't be surprised to find that several surfactants .

SLC46A3 Is Required to Transport Catabolites of .

rotovap to yield a solid residue. The residue was purified by preparative HPLC (Luna Silica, 21.2 150 mm, 5 mm column; 20 mL/minute isocratic elution; 20% acetonitrile/MTBE) to yield 994 mg of DM1-SMCC (8) as a white solid (73% yield, potency adjusted). Generation of ADC Anti-EGFRvIII Ab-MCC-DM1 was conjugated as previously described (16).

Vapor Pressure of Methanol from Dortmund Data Bank

Vapor Pressure of Methanol. The experimental data shown in these pages are freely available and have been published already in the DDB Explorer Edition.The data represent a small sub list of all available data in the Dortmund Data Bank.For more data or any further information please search the DDB or contact DDBST.. Component

Preparing Anhydrous Reagents and Equipment | Protocol

Tetrahydrofuran (THF) on the other hand should be dried for a duration of 3 days using 20% m/v of 3-Å molecular sieves to reach low residual amounts of water of about 4 ppm. Lower-mass alcohols such as methanol or ethanol should even be stored about 5 days over 3-Å molecular sieves and 20% m/v, which will yield residual water content of 8 .

PowerPoint Presentation

Distillation of a mixture containing tetrahydrofuran and diethyl ether. Glass fragments into her face and upper torso. What happened? Above is a photo of what remained after the explosion. Note that the lower round- bottomed flask from the rotovap exploded inside the metal water bath. .

Reducing Agents | Protocol - JoVE

After purging, inject 10 mL of dry tetrahydrofuran and lower the flask into an ice bath. When the other preparations are complete, make a solution of 0.127 mL of ethyl acetoacetate and 3 mL of dry THF. Inject this solution dropwise into the flask. . or rotovap. Next, use TLC to check the purity of the product. Then, analyze the product with .

Methyl Migration to Coordinated CO

THF is removed on the rotovap to afford the crude product. 2nd Lab Period Part A: Preparation of Cyclopentadienylmethyliron dicarbonyl (5) continued. Extract the crude product with pentane and filter. Rotovap the resulting orange solution to afford solid compound 5. Product Characterization: Record the 1H NMR spectrum of 5 in CDCl

How To - University of Rochester

©2020 Alison Frontier, University of Rochester. Supported by a grant from the National Science Foundation. NSF Funding {+} This material is based upon work supported by the National Science Foundation under Grant Number CHE-1565813. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect .

Lignin-methyl methacrylate polymer as a hydrophobic .

In this work, the modification of lignin (KL) with methyl methacrylate (MMA) is presented via free-radical polymerization in the presence of potassium.

rotovap - Laboratory equipment - Verrerie Villeurbannaise

evaporateur rotatif, rotovap, en verre, digital, numerique, analogique,automatique pour laboratoire

Reducing Agents | Protocol - JoVE

After purging, inject 10 mL of dry tetrahydrofuran and lower the flask into an ice bath. When the other preparations are complete, make a solution of 0.127 mL of ethyl acetoacetate and 3 mL of dry THF. Inject this solution dropwise into the flask. . or rotovap. Next, use TLC to check the purity of the product. Then, analyze the product with .

Sequential depletion of myeloid-derived suppressor cells .

After polymerization at 65 °C for 12 h, the product was diluted with tetrahydrofuran (THF), which was then passed through the Al 2 O 3 column to remove the catalyst. The THF solvent was removed by rotovap. The product was dialyzed in distilled water three .

CHEM 213 Technique Experiments

CHEM 213 Technique Experiments Experiment 7: Column Chromatography Number of labs - one Reactions performed – None Chemicals used: Fluorene-fluorenone mixture, hexanes, methylene chloride, silica gel Supplies needed: Various sized beakers, chromatography column Techniques: Column chromatography, rotovap Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, .

A nanobuffer reporter library for fine-scale imaging and .

After 8 h polymerization at 40 °C, the reaction mixture was diluted in 10 ml tetrahydrofuran (THF), and the mixture was passed through a neutral Al 2 O 3 column to remove the catalyst. The organic solvent was removed by rotovap. The residue was dialysed in distilled water and lyophilized to .

Pressure-Temperature Nomograph Interactive Tool | Sigma .

Calculate a boiling point or pressure using the Antoine Equation: The Pressure-Temperature Nomograph is a graphical application of the Clausius-Clapeyron Equation, which assumes the heat of vaporization is a constant over a pressure range.

Nitrogen Evaporators: Making Sample Concentration Easier .

When a scientist needs to concentrate a sample that's in a volatile liquid—like acetone, acetonitrile, or methanol—a nitrogen evaporator can do the job. As a result, scientists use this technology in sample preparation in environmental, polymer science, quality control, and toxicology labs, plus others.