Portable Chillers | Process Chillers | Low Temp Fluid Chillers

Low Temperature Fluid Chillers. Thermonics portable chillers are a family of highly reliable, process chillers for low and ultra-low temperature, process cooling. . Water Cooled Chillers . Model Temperature Range (°C) Stability (°C) Cooling Capacity (kW @ 20°C Water Supply) Pump Capacity (GPM/LPM) 25 0-20-40-45-60-70-80; W-40-1100-40 to +50

60 kW Low Temp Reverse Cycle Chiller - Active Air

The versatile 60 kW reverse cycle chiller not only provides heating and cooling, it also has a low temp option. With the capability of a much larger machine, it really .

Chiller vs Air Conditioner: The Differences You Should .

A chiller system usually works along an absorption refrigeration cycle to remove heat from an area. They take hot water, cool it down in its liquid form, and this 'chilled' water circulates the building. This water also goes through fan-coil units, which allow the liquid to pass through them and, subsequently, help dehumidify a room as well.

Air-Cooled Chillers | YORK®

Air-cooled Chillers Engineered for Low Total Cost of Ownership. With a wide range of types, capacities and sustainable refrigerant options, YORK® is a leader in air-cooled chiller solutions. We engineer compact, energy-efficient chillers that are easy to maintain and are tailored to fit almost any application.

Low Temperature Test Chillers | Opti Temp

Low Temperature Chillers Low temperature process cooling, extreme low temperature cooling and standard temperature cooling systems, designed by Opti Temp, Inc. . Air or water cooled condensers. Chillers can be manufactured in either air or water cooled heat exchange systems. Air cooled systems liberate waste heat to the environment where .

Centrifugal Chiller - Fundamentals | Energy-Models.com

Modern chiller controls are DDC based and employ PID (proportional-integral-derivative) loops for stable control. The control parameter is the supply chilled water temperature. The controller measures the supply chilled water temperature and modulates the chiller capacity to maintain the setpoint. McQuay chillers control to ± 0.2 o F.

AquaForce® 30HX High-Efficiency Indoor Liquid Screw Chiller

75 to 265 Nominal Tons. 30HXA - Condenserless 30HXC - Water-Cooled. The 30HX units are high-efficiency, indoor water-cooled or condenserless chillers. The units have a quiet, low-vibration design featuring screw compressors.

Adsorption Chiller - an overview | ScienceDirect Topics

This company has also produced zeolite-water adsorption chillers with capacities of 105, 215, and 430 kW (0.0043 to 0.0067 kWe per kW of cooling capacity). The heat source (hot water) temperature is 68 °C, the cooling water is 27 °C, and the chilled water temperature is 15 °C.

blessing or curse? Hot Gas Bypass

any liquid from the HGBP line lessens this requirement. Size the line for a pressure drop of 6 psid to 20 psid. Keep the HGBP line short. Refrigerant vapor will condense in, and fill any portion of, the HGBP line that is colder than the saturated temperature of the suction or discharge gas. Incidences (and consequences) of refrigerant

How Does a Chiller Work? See our Chiller Diagram

In the case of chillers, heat is taken from the fluid being chilled and transferred to the ambient air. The Compressor; The refrigeration cycle begins with the compressor. The compressor takes low-pressure low-temperature refrigerant in gas form and compresses it into a high-pressure high-temperature .

Chiller - Wikipedia

A chiller is a machine that removes heat from a liquid via a vapor-compression, Adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water). As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater .

YIA Single-Effect Absorption Chillers Steam And Hot Water .

the pipes. Adjustable limits on the low water temperature setpoints allow the chiller to cycle on and off for greater ef-ficiency and less chiller cycling. The chiller cycles off when the leaving chilled water temperature is below setpoint and is adjustable from 1°F (0.55°C) below to a minimum of 40°F (4.4°C).

Basics of Low-temperature Refrigeration - CERN

Basics of Low-temperature Refrigeration A. Alekseev 1. Linde AG, Munich, Germany . Abstract . This chapter gives an overview of the principles of low temperature refrigeration and the thermodynamics behind it. Basic cryogenic processes - Joule-Thomoson process, Brayton process as well as Claude process are - described and compared.

HOT WATER DRIVEN CHILLERS - Konark Global Konark .

Low temperature Hot Water. Low temperature hot water chillers are further classified as Low Capacity (LT Series) and High Capacity (5G Series) Cogenie (LT Series) Cogenie is a simple and compact small capacity single effect hot water chiller.

HVAC and Refrigeration Compressor Troubleshooting Chart

Low outside air temperature on an air cooled system. . Chiller systems; frozen or slushed or low water flow. Suction pressure - Fluctuating. Incorrect superheat setting. Expansion valve bulb not mounted properly. Restricted external equalizer line. . Liquid migration on the off cycle. Install pump down controls and a crankcase heater.

Industrial Refrigeration Basics - The Engineering Mindset

Feb 07, 2019 · The refrigerant which is liquid falls down and repeats the cycle through the evaporator, and the refrigerant which is vapour, rises and is sucked back into the compressor to repeat the entire cycle again. The refrigerant enters the compressor as a low pressure vapour refrigerant. Two stage ammonia industrial refrigeration system

Absorption Chillers Overview | Alabama Power

Smaller absorption chillers sometimes use water as the absorbent and ammonia as the refrigerant. As you can probably guess, the absorption chiller must operate at very low pressures (about l/l00th of normal atmospheric pressure) for the water to vaporize at a cold enough temperature (e.g., at ~ 40iF) to produce 44iF chilled water.

Glycol Chillers - Industrial Water Chiller Manufacturer

Thus, a water/glycol brewery chilling system can cool wort much faster than a water-only chiller without producing harmful ice in the insides of the brewing vessel. For the most efficient cooling, many companies use a water/glycol mix of about 67% to 33% in industrial glycol chillers.

60 kW Low Temp Reverse Cycle Chiller - Active Air

The versatile 60 kW reverse cycle chiller not only provides heating and cooling, it also has a low temp option. With the capability of a much larger machine, it really .

HVAC/R Refrigerant Cycle Basics - HVAC School

Mar 01, 2019 · Boiling is actually just a change of state from liquid to vapor, and the temperature that occurs varies greatly based on the substance being boiled and the pressure around the substance. In an air conditioner or a refrigeration system, refrigerant is designed to boil at a low temperature that corresponds to the design of the system.

16JL/JLR16LJ Single-Effect Steam/Hot Water Absorption .

Carrier's 16JL/JLR steam/hot single effect, hermetic absorption liquid chiller is an efficient and functional alternative to traditional electric driven chillers. By utilizing low pressure steam or low-temperature hot water, 16JL/JLR chillers avoid high-cost electricity and qualify for utility rebates and incentives as a gas cooling product.

HVAC Chilled Water Distribution Schemes

Higher return water temperature leads to higher loading of chillers. Impact of Low delta-T (∆T) syndrome Low ∆T can be a serious problem for constant flow system because it robs chiller of its useful capacity. For example, if chiller is receiving return water temperature of 52°F rather than the design return water temperature of 55°F, the .

Low Temperature Circulation Chiller, Refrigerated .

Low Temperature Circulation Chiller, Refrigerated Circulators temperature reach -25°C, -30°C, -40°C, -50°C, -60°C, -80°C, -100°C, -120°C and etc. Closed Cycle Cooling Machine, CE ISO certificated.

Chiller vs Air Conditioner: The Differences You Should .

A chiller system usually works along an absorption refrigeration cycle to remove heat from an area. They take hot water, cool it down in its liquid form, and this 'chilled' water circulates the building. This water also goes through fan-coil units, which allow the liquid to pass through them and, subsequently, help dehumidify a room as well.

Industrial Heating and Cooling Equipment

Temptek offers high quality industrial heat transfer equipment for many applications, since 1988.

Adsorption Chiller - an overview | ScienceDirect Topics

This company has also produced zeolite-water adsorption chillers with capacities of 105, 215, and 430 kW (0.0043 to 0.0067 kWe per kW of cooling capacity). The heat source (hot water) temperature is 68 °C, the cooling water is 27 °C, and the chilled water temperature is 15 °C.

Absorption Chiller, How it works - The Engineering Mindset

Sep 26, 2017 · If water is placed into a vacuum chamber then it will boil at extremely low temperatures. So in the absorption chiller both the evaporator and absorber chamber are kept at near vacuum conditions at around 0.84kPa (0.12psia). This allows the water to boil at around 4.5°C (40°F) so very little energy is required.

Custom Aluminum Industry Water Cooled Chiller Price, China .

Our company various industrial chiller with competitive price include: water chiller machine for supermarket; Semi closed Screw Type Chiller; 100 ton Refrigerant Air cooled Heat Pump Unit; school Scroll Type Pump Water Heater; -30 degree low temperature water chiller for agriculture.

The Ultimate Guide to Chiller Systems. Everything You Need .

Chillers provide a continuous flow of coolant to the cold side of a process water system at a desired temperature of about 50°F (10°C). The coolant is then pumped through the process, extracting heat out of one area of a facility (e.g., machinery, process equipment, etc.) as it flows back to the return side of the process water system.

How Does A Chiller Work? - What Is A Chiller & How To .

The refrigeration cycle starts with a low-pressure liquid/gas mix entering the evaporator. In the evaporator, heat from the process water or water/glycol solution boils the refrigerant, which changes it from a low-pressure liquid to a low-pressure gas. The low-pressure gas enters the compressor where it is compressed to high-pressure gas.