Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

ORGANIC LABORATORY TECHNIQUES 8 8.1 ROTARY .

evaporation flask is carefully attached to the ground glass joint and secured with a clip (don't use grease). If the flask neck size doesn't match the joint on the rotary evaporator, then a reduction adaptor needs to be used. Start the flask rotating. Place your finger or thumb over the vent hole and use it to control the vacuum.

Rotary Evaporators | Glen Mills, Inc.

Rotary Evaporators. Showing all 2 results. Filters. Rotary Evaporators Eyela N-1300E·V·S Rotary Evaporator. Rotary Evaporators Eyela N-1300E·V·S Rotary Evaporator . By using joint adapter and vacuum seal (option), Ts 29/38 sample flask can be used. SKU: n/a. Add to Wishlist. Compare. Showing all 2 results. Show All Categories.

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

With an innovative and ergonomic design, the EV series rotary evaporators include color digital display . 4 50103-CS Ball Joint Clamp 5 50103-SR3 Lock Handwheel 50103-0050 50 mL 29/32 50103-0100 100 mL 29/32 50103-0250 250 mL 29/32 50103-0500 500 mL 29/32 50103-1000 1000 mL 29/32

Rotary Evaporators, the Büchi Rotavapor® R-300

Büchi Rotavapor R-300 Rotary Evaporator with Electronic Lift, B-305 heating bath, complete with vertical condenser in plastic coated glass-ware, 24/40 joint, B-305 heating bath, I-300 Pro interface and Buchi F-305 chiller, 115 V, 60Hz Inquire: 11SR300252VS2

CG-1318 - ADAPTERS, ROTARY EVAPORATORS, VIALS- .

adapters, rotary evaporators, vials Adapters permit the connection of standard laboratory dram sample vials directly to the vapor tube or a bump trap of a rotary evaporator. Adapters have a top outer joint of the listed size and a 20-400 G.P.I. thread at the bottom.

ROTARY EVAPORATORS - 2L - Page 1 - USA Lab

USA Lab 2L Rotary Evaporator Turnkey Rotovap RE-200A w/ Vacuubrand MZ 2C NT. New The USA Lab 2L RE-200A Series rotary evaporator Turn-Key kit recovers solvents efficiently an 5,399 . 1000mL Spherical Joint Round Bottom Receiving Flask - 1 neck 35/20. New Our 1L S35/20 1 Neck Spherical Joint Round Bottom flask is constructed with 3.3 Borosilic

Rotary 1 Evaporators - Labplant

Rotary evaporator innovations The following are the technical innovations applied to the construction of the STRIKE 300 Rotary Evaporator making it a fast, working, efficient, safe and maintenance free instrument. Flask assembly System used to assemble the evaporation flask. The evaporation flask is screwed onto the steam passing pipe

Rotary Evaporators | Fisher Scientific

Rotary Evaporators Heidolph™ Hei-Vap™ Rotary Evaporators - Hei‐VAP Value/Hei‐VAP Value Digital Affordable model with hand lift for all standard applications

How to use a Rotary Evaporator

A typical rotary evaporator has a water bath that can be heated in either a metal container or crystallization dish. This keeps the solvent from freezing during the evaporation process. The solvent is removed under vacuum, is trapped by a condenser and is collected for easy reuse or disposal.

Buchi R100 Rotary Evaporator | Asynt

The rotary evaporator R-100 is a high-quality, entry level Rotavapor to meet the essential needs in classical laboratory applications. It is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual lifting of the evaporating flask.

Rotary evaporators - Stuart Equipment

• Rotary evaporator with cold finger glass condenser for use with ice or dry ice for volatile or low boiling solvents. No cooling water . with stopcock, vacuum seal, conical joint clip, spherical joint clip. Glass set 00P Diagonal coil condenser plastic coated, vapour tube for diagonal condenser,

5.5B: Step-by-Step Procedures for Rotary Evaporation .

Aug 18, 2019 · Rotary Evaporation Procedure Figure 5.67: a) Sample to be evaporated, b) Attachment of sample to bump trap on rotary evaporator, c) Lowering of sample into water bath. If your institution uses a water circulator connected to the condenser to minimize water usage (open cabinet of Figure 5.65), be sure that there is ice in the water reservoir.

Inlet Feed Adapter for Rotary Evaporator - Complete - Buy Now

Normally, you would have to turn the vacuum off, refill the evaporation flask, and start the run all over again. Now, with a continuous lab flow, you can save time and money. These inlet feed adapters work with all rotary evaporators that have a 19/38 inlet joint.

Basic Rotary Evaporator with Motorized Lift & Digital .

Rotary joint's locking position is adjustable within 80 mm; especially useful when using varying capacity evaporating flasks or when there is a need to shift the vacuum seal's contact position (Patent No. 3220033) Evaporation flasks are easily removable with built in flask remover

Rotary Evaporator Replacement Glassware

6 ROTARY EVAPORATOR REPLACEMENT GLASSWARE Or 18002234524 • B uchi R eplacement G lass c omponents 13285 Vapor Duct Tubes (w/o combi clip) Joint Fits Buchi Models Length, mm (A) For Assy. Buchi Part # Order Code 29/32 210-215 160 A 46964 13285-04* 24/40 210-215 160 A 48068 13285-06* 29/32 210-215 54 V 46962 13285-08* 24/40 210-215 54 V 48067 .

Yamato Re-801 Rotary Evaporator, Bo-400 Oil Bath (4L .

Adjustable Rotary Joint The rotary joint's locking position feature is adjustable up to 80 mm: useful when using evaporating flasks with varying capacities or when there is a need to shift the vacuum seal's contact position. . Yamato Re-301 Rotary Evaporator, Vr-300 Vacuum Regulator, Bm-500 Water Bath (4L), Glassware C (For low boiling point .

Rotary Evaporators, the Büchi Rotavapor® R-300

Büchi Rotavapor R-300 Rotary Evaporator with Electronic Lift, B-305 heating bath, complete with vertical condenser in plastic coated glass-ware, 24/40 joint, B-305 heating bath, I-300 Pro interface and Buchi F-305 chiller, 115 V, 60Hz Inquire: 11SR300252VS2

CG-1318 - ADAPTERS, ROTARY EVAPORATORS, VIALS- .

adapters, rotary evaporators, vials Adapters permit the connection of standard laboratory dram .

Rotary Evaporators | Fisher Scientific

Rotary Evaporators Heidolph™ Hei-Vap™ Rotary Evaporators - Hei‐VAP Value/Hei‐VAP Value Digital Affordable model with hand lift for all standard applications

How does a rotary evaporator remove solvent

How does a rotary evaporator remove solvent. The rotary evaporator is mainly used to continuously distill a large amount of volatile solvents under reduced pressure, such as extraction by distillate and a receiving liquid for chromatographic separation.The basic principle of a rotary evaporator is to evaporate sample materials with evaporation flask's continuous rotation.

Heidolph Instruments : Rotary Evaporators

In close cooperation with users, we developed the Hei-VAP series of rotary evaporators with an emphasis on the essentials: well thought-out details with a focus on features and functions to facilitate everyday laboratory work. Versatile combinations with glassware and extensive accessories offer the right configuration for every application.

BUCHI Rotavapor R-100 Rotary Evaporator Systems .

BUCHI Rotavapor™ R-100 Rotary Evaporator Systems The Rotavapor R-100 is capable of manually adjustable rotation speed of 20 to 280rpm and equipped with action jack lift for manual lifting of evaporating flask.

How to use a Rotary Evaporator

A typical rotary evaporator has a water bath that can be heated in either a metal container or crystallization dish. This keeps the solvent from freezing during the evaporation process. The solvent is removed under vacuum, is trapped by a condenser and is collected for easy reuse or disposal.

Rotary Evaporator for sale in UK | View 58 bargains

2L 0-99℃ 0-120rpm New Lab Rotary Evaporator w/Moto 2l 0-99℃ 0-120rpm new lab rotary evaporator. This has the plastic safety film and is in perfect unused condition. it is a device that uses the technique of solid distillation at low temperatures using a vacuum pump.

Shop Rotary Evaporators & Rotovaps [Price Matched]

What are rotary evaporators? A rotary evaporator (or rotavap or rotovap) uses precise engineering to effectively remove solvents from a sample using evaporation. Most rotovaps make use of a vacuum and pressure control monitor to precisely control pressure within your system, increasing evaporation efficiency.. In many commercial labs, these machines need to be running around-the-clock without .

Development and Evolution of Rotary Evaporator - Lab .

Maybe, Bacher suggests, a rotary evaporator could include fewer joints in general to reduce the sources of leaks. For example, he says, "While I do understand why the receiving flask is attached with a ball joint, I feel it generates a significant problem as well because most round-bottom flasks used in the lab have normal ground glass joints."

BUCHI Rotavapor R-100 Rotary Evaporator Systems .

BUCHI Rotavapor™ R-100 Rotary Evaporator Systems The Rotavapor R-100 is capable of manually adjustable rotation speed of 20 to 280rpm and equipped with action jack lift for manual lifting of evaporating flask.

Rotary Evaporators at Thomas Scientific

The rotary evaporator R-100 is a high-quality, entry level Rotavapor to meet the essential needs in classical laboratory applications. It is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual lifting of the evaporating flask. Included is.

Rotary evaporators - Stuart Equipment

• Rotary evaporator with cold finger glass condenser for use with ice or dry ice for volatile or low boiling solvents. No cooling water . with stopcock, vacuum seal, conical joint clip, spherical joint clip. Glass set 00P Diagonal coil condenser plastic coated, vapour tube for diagonal condenser,

Rotary Evaporator Replacement Glassware

6 ROTARY EVAPORATOR REPLACEMENT GLASSWARE Or 18002234524 • B uchi R eplacement G lass c omponents 13285 Vapor Duct Tubes (w/o combi clip) Joint Fits Buchi Models Length, mm (A) For Assy. Buchi Part # Order Code 29/32 210-215 160 A 46964 13285-04* 24/40 210-215 160 A 48068 13285-06* 29/32 210-215 54 V 46962 13285-08* 24/40 210-215 54 V 48067 .