We Cherish All Interactions
Magnetic agitator with shaft of high pressure laboratory reactors : The MagneDrive® agitator uses rare earth magnets, permitting packless mixing at higher speeds and with higher viscosity fluids. Outer drive magnets, rotated by a motor driven belt exert powerful attraction on .
Laboratory reactors come in a variety of sizes, shapes and . In-line mixing devices can be placed in the flow path to promote thorough mixing of the fluid. The reactor must be operated at a very high recirculation rate, and the pump and other components must be . liquid-phase, bimolecular reactions. Solutions containing the
biotechnology among others) is performed in small glass reactors. From this lab small glass reactors experience is common to obtain kinetic constants and mixing effects. Akiti [2005] demonstrated the dissimilarity of these reactors since a small glass reactor is not an ideal reactor.
Ultrasonic batch mixing works well for volumes of up to 100L for some purposes, however ultrasonic in-line mixing using flow cell reactors and a feed pump is the more effective solution. In a flow cell the ultrasonic power is highly concentrated on a small .
Agitator, Mixers and Impellers - Liquid Handling Equipment. Agitator Manufacturers: Mix Mor Corporation Portable, Side Entering Turbine Mixers MixMor continues to be a leading manufacturer of high quality mixers with more than 50 years experience, offering a complete line of mixers including Laboratory, Portable Clamp-on, Fixed Mount Top Entering, Side Entering and Turbine MixersMixMor .
Both AD reactors were fitted with the mixing systems being studied, but only one of them had the nozzle and ring assembly. The reactors were also hydraulically mixed by passing the contents through the heat exchangers at a rate of 60 m 3 per hour. The gas flow and gas composition from each reactor was measured and recorded.
The L5M-A Laboratory Mixer is suitable for the widest range of applications – mixing, emulsifying, homogenizing, disintegrating and dissolving – with an efficiency and .
Mixing is performed to allow heat and/or mass transfer to occur between one or more streams, components or phases. Modern industrial processing almost always involves some form of mixing. Some classes of chemical reactors are also mixers. With the right equipment, it is possible to mix a solid, liquid or gas into another solid, liquid or gas.
The LR 1000 basic is a cost efficient, modular laboratory reactor designed for optimizing chemical reaction processes as well as for mixing, dispersing and homogenization applications at the laboratory scale. The reactor is especially designed for the unique applications requirements that define the cosmetic and pharmaceutical industries.
Jul 07, 2017 · The unique hydrogenation pilot plant offers optimal conditions in an explosion-proof laboratory to investigate the interaction of chemistry and mixing technology at realistic operating conditions.
The liquid fluoride thorium reactor (LFTR; often pronounced lifter) is a type of molten salt reactor.LFTRs use the thorium fuel cycle with a fluoride-based, molten, liquid salt for fuel.In a typical design, the liquid is pumped between a critical core and an external heat exchanger where the heat is transferred to a nonradioactive secondary salt. The secondary salt then transfers its heat to a .
The EKATO GROUP companies offer optimized mixing technology, from modular, robust, and rapidly available industrial agitators over individual solutions for reactor agitators in sophisticated mixing processes up to complete process plants including automation.
The thermowell can be used to support suspended stirrers (PTFE, stainless, or Hastelloy) in order to improve mixing. The small size is ideal for reducing chemical inventories for screening runs, and provide excellent data for selecting the chemical systems to proceed to larger-scale testing. 75, 160, 300 or 400 ml working volumes
Laboratory reactors: Collection and analysis of the data Chapter objectives Chemical reaction tests in a laboratory A perspective on statistical experimental design Batch laboratory reactors Rate parameters from batch reactor data Flow reactors for testing gas–solid catalytic reactions The transport disguises in perspective Analyzing the data .
Mixing non-Newtonian fluids may be doubly complicated when the mixing process creates the non-Newtonian proper-ties. For example, a formulation process may start with a low-viscosity liquid, and mixing causes the viscosity to increase until the fluid becomes non-Newtonian. Sometimes mixer power may be used as an indicator of final fluid viscosity.
Fisco-1H Fisco-2H Fisco-1S Fisco-2S Fisco-5S Fisco-1S-A Fisco-2S-A Fisco-5S-A Fisco Lab Reactor. PLM Powder & Liquid Mixing System . PD10-XT Magnetic Stirrer. FCH202 FCH202-S FCH203 .
Bachlab, laboratory vacuum mixer and reactor for liquids and creams, allows a wide range of processes to be performed, such as homogenisation, dispersion, emulsion and deaeration.. It obtains highly stable emulsified products thanks to its coaxial stirring assembly and a new Rotor-Stator system with a high shearing power, allowing the developing of high viscosity and complex rheology products.
The standard Laboratory Reactor System 1 is an immersion-type photochemical reactor with implemented magnet-driven circulation pump, which provides a complete mixing of the reaction liquid.
Table 4-5 Effect of reactor design on size and productivity for a gas-liquid reaction Batch stirred Reactor type tank reactor Loop reactor Reactor size (1) 8,000 2,500 Chlorination time (hr) 16 4 Productivity (kg/hr) 370 530 Chlorine usage (kg/100 kg product) 33 22 Caustic usage in vent scrubber 31 5 (kg/100 kg product) Source: Center for .
very small gas bubbles to the liquid (30 to 70 µm) with a gas-liquid ratio between 0.5 and 2.0, or even more, makes this an ideal tool as primary dispersion device for gas-liquid reactors. The two-phase mixture created in the reaction mixer is then injected into the fluid of the reaction vessel. (2) The reaction vessel of an ABLR reactor does .
The most important difference present in many liquid phase reactions is the phenomenon of micro-mixing, or mixing at the molecular scale. In the reaction shown in Fig. 10, whether the reaction will preferentially form product S or product R depends on the physical configuration of the reactor.
Jan 10, 2018 · Fluid regimes in the lab often are laminar or transitional due to the small vessel sizes. For this reason, effective small-scale mixing studies frequently require simulant fluids to mimic the expected full-scale Reynolds number. Unusually high or low power intensities. For higher power intensity reactor agitators, use four baffles.
Batch mode - Mixers/Reactors. Using a mixer in batch mode offers a huge flexibility to optimize the mass transfer by varying ratio of the liquid phases, the type of stirrer, stirrer speed and mixing time. The settling period can also be easily influenced by varying the time.
Nov 24, 2016 · The laboratory reactor is ideally suited for processing high-viscosity samples at highest temperatures. magic LAB. The magic LAB is a unique and multi-functional small-scale laboratory machine. It is designed for mixing, dispersing, wet milling, and incorporation of powders into liquids.
LR-2.ST Lab Reactor: The IKA® LR-2.ST system is a modulary designed miniplant reactor system, planned and designed to simulate and optimize chemical reaction processes as well as mixing, dispersion and homogenization processes at a model scale with a maximum volume of 2000 ml.
Magnetic agitator with shaft of high pressure laboratory reactors The MagneDrive® agitator uses rare earth magnets, permitting packless mixing at higher speeds and with higher viscosity fluids. Outer drive magnets, rotated by a motor driven belt exert powerful attraction on .
The standard Laboratory Reactor System 1 is an immersion-type photochemical reactor with implemented magnet-driven circulation pump, which provides a complete mixing of the reaction liquid. The irradiation is effected by means of a medium pressure UV lamp (150 Watt), operated by utilizing a vertically arranged combination-tube (immersion tube .
The batch reactor in the laboratory is typically loaded with materials and heated to a desired temperature. Then, after a given time, the reactor is brought to room temperature and the contents are analyzed. . Perfect mixing is assumed for this ideal reactor, . Typical batch reactors for kinetic studies of liquid-phase reactions at ambient .
The magic LAB ® is a multifunctional small-scale laboratory machine that is built to handle mixing, wet milling, dispersing, and merging of powders into liquids. The magic LAB ® is most regularly used for the advancement of new products or for improving current process methods, mainly in the cosmetic, chemical, food, and pharmaceutical industries. It is a suitable machine for nonstop .
Liquid-liquid mixing is a key process in industries that is commonly accomplished in mechanical agitation systems. Liquid-liquid mixing performance in a stirred tank can be evaluated by various parameters, namely minimum agitation speed, mixing time, circulation time, power consumption, drop size distribution, breakup and coalescence, interfacial area, and phase inversion.